Open Mon–Sun 6am–midnight · (714) 489-5886
The Backflow Testers of Whittier

Backflow Preventer Testing in Whittier

Every preventer type tested to its own procedure.

RP: relief valve and both checks. Double check: both checks. PVB and SVB: air inlet and check. Fire line detector assemblies: main and bypass. We run the right procedure and file the results. Price goes by size.

  • Price$105 flat
  • TimeUnder an hour
  • SchedulingSame week
  • FilingIncluded

Pricing

Backflow sizeFlat fee per backflow
Under 4"$105
4" and larger$175

Includes the test and filing with your water district. No hidden fees.

Devices we test

  • Pressure vacuum breakers (PVB)
  • Double check valve assemblies
  • Spill-resistant vacuum breakers (SVB)
  • Fire line detector assemblies (DCDA, RPDA)
  • Reduced pressure (RP or RPZ) assemblies

Book now. Same-week visits.

How we test an RP or RPZ

A reduced pressure principle assembly, often called an RP or RPZ, is the device used on high-hazard connections. It has two check valves with a relief valve between them. If either check leaks, the relief valve opens and dumps water out of the bottom instead of letting it travel backward.

Testing an RP takes a few more steps than other devices. The tester checks the point where the relief valve starts to open, then checks the first check valve and the second check valve to make sure each one holds tight.

Because RPs protect against the worst kinds of contamination, districts watch them closely. A relief valve that drips during normal use is a common sign that the first check is fouled or worn. We'll point that out even if the device squeaks by on test day, since it usually means a failure is coming.

Testing double check valve assemblies

A double check valve assembly has two independent check valves in a row and no relief valve. It's approved for lower-hazard connections, like many fire sprinkler systems and some irrigation and domestic lines.

The test confirms that each check valve holds pressure in the direction it's supposed to. The tester isolates each check in turn using the shutoff valves and test cocks, then reads the gauge.

Double checks are often installed below ground in vaults or boxes, especially on fire lines. That can make access the hardest part of the job. If your device sits in a vault that fills with water or dirt, let us know when you book so we come ready to pump it out before the test.

Testing PVBs and SVBs

Pressure vacuum breakers (PVBs) and spill-resistant vacuum breakers (SVBs) are the devices you see sticking up above ground on a lot of Whittier sprinkler systems. They protect against backsiphonage, which happens when pressure on the street side drops and water could get pulled back out of your lines.

Each has a spring-loaded check valve and an air inlet that opens to break a vacuum. The test confirms the air inlet opens when it should and the check valve holds.

These devices have to sit higher than every sprinkler head or outlet downstream of them. If yours was installed too low, it may pass the test but still not meet code. We'll mention it if we see it, so you're not surprised by a district inspection later.

Testing devices on fire sprinkler services

Many commercial and multi-unit buildings have a double check detector assembly (DCDA) or a reduced pressure detector assembly (RPDA) on the fire sprinkler line. These have a small bypass with a meter that shows if water is being used on the fire line when it shouldn't be.

We test the main assembly and the bypass assembly, since both protect the water supply. Fire line devices are often 4 inches or larger, which falls in the $175 per device price tier.

Fire systems usually involve more than one party: the building owner, the fire sprinkler contractor and sometimes the fire department. Closing valves on a fire line can trigger alarms, so we coordinate with you first and follow the steps needed to keep the system covered.

Identifying your device

The type is usually printed on the device or a tag attached to it. Without a label, look at the shape. RPs have a relief port underneath between two checks. Double checks have two check covers and no relief port. PVBs and SVBs have a bonnet on top.

There's no need to figure it out yourself. Send a photo when you book, or let the tester identify it when they arrive.

Older devices and test results

Condition counts more than type. A well-maintained older device often passes without trouble, and a newer one on a dirty line can fail.

Age still plays a part, since rubber and springs wear out over time. When a device gets old enough that parts are hard to source, we'll tell you so you can plan a replacement on your schedule instead of in a hurry.

Don't know which one you have?

A quick photo is usually enough for us to tell. Or read our comparison guide.

Why Whittier calls us

Certified testers. Calibrated gauges. Reports filed with your water district as part of every job. Prices given before any work starts.

Testing is $105 flat under 4 inches and $175 for 4 inches and up. We pick up seven days a week, 6am to midnight, book most visits within the week and take emergency calls 24/7.

What happens after you call: we confirm the address and device, give you a time window, and show up in it. The tester checks the device, runs the test and tells you the result on the spot. Pass: the report is filed that day. Fail: you get the reason and the price, and most repairs are done before we leave. Either way, you get a copy of everything for your records. Have several devices or properties in Whittier? Ask about multi-device pricing and due date tracking when you call.

Questions

Which type is most common on homes?

On sprinkler lines it's usually a PVB or double check. On the main line it's often a double check or RP.

Is an RPZ the same as an RP?

Yes. Both names refer to a reduced pressure principle assembly.

Can you test a device installed underground?

Yes. Let us know when you book if the vault fills with water or dirt so we come ready to clear it.

Do fire line devices need the fire department?

Usually not for the test itself, but we coordinate with you first since closing valves can trigger alarms.

Is the price different for an RP?

No. We charge by size: $105 under 4 inches, $175 for 4 inches and larger.

Do all types cost the same to test?

Pricing goes by size, not type: $105 for devices under 4 inches and $175 for 4 inches and up.

Where we work

We offer backflow preventer testing in Whittier, South Whittier, West Whittier-Los Nietos, Pico Rivera, Santa Fe Springs and Hacienda Heights. Same-week visits.

Need a test?

Same-week visits in Whittier. Paperwork included.

Call nowBook online