RPs above grade. Vacuum breakers above the highest outlet. Room for testing and repairs. Cages where theft is a risk. Startup test and first report included.
- PriceFree quote
- TimeUsually 1 day
- TestIncluded
- FilingIncluded
Installation rules we follow
- Cages or covers where theft or freezing is a risk
- Easy access for annual testing
- PVBs and SVBs set high enough
- Relief valves free to drain
Book now. Same-week visits.
Placement and height
An assembly's location affects both how it works and whether it passes inspection. RPs have to be above grade with clearance below so the relief valve can drain. An RP in a vault or a flooding box is a frequent problem.
PVBs and SVBs need to sit above every sprinkler or outlet they protect, generally by 12 inches or more. On sloped lots, that may put the device uphill rather than near the meter.
Double checks can go in vaults, which is common on fire lines, but they still need room around them for testing and repairs.
Leaving room to test and service
Since every assembly gets tested yearly, it has to be easy to reach. Testers need space for the gauge hoses at the test cocks, room to turn the shutoffs, and enough clearance to open the checks for repairs.
A device crammed against a wall, hidden in bushes or tucked into a tight ceiling space can make a quick test drag on, or make a repair require cutting pipe. We plan the install so that doesn't happen.
Access for testers matters too. Behind a gate is fine at a house. At a business, a spot testers can reach without an escort saves everyone time.
Freeze and theft protection
Southern California doesn't freeze often, but it does happen in some inland and higher-elevation areas. A single cold night can crack a brass body or bonnet. Insulated covers or enclosures help where it's a risk.
Theft is a bigger concern in many neighborhoods. Brass backflow assemblies near streets and parking lots are targets for scrap thieves, and a stolen device leaves an open pipe and an urgent repair. Locking cages bolted to a concrete pad are the usual answer.
We'll recommend protection based on where the device is going. If you'd like a cage or cover, it can be added to the installation quote.
Startup test and the first report
Once an assembly is installed and the lines are flushed, we run the startup test. This is the same procedure used each year, and it confirms the device was installed correctly and works as designed.
The passing report is filed with your water district, which adds the device to its records and sets the first annual due date. You get a copy for your files.
From then on, the device needs an annual test. We can remind you before it's due, or you can add due date management and we'll handle the scheduling every year.
Raising or relocating an existing assembly
Some assemblies were installed in the wrong spot years ago: an RP in a pit, a PVB below the sprinklers or a device boxed in where no one can test it. Moving it is often the right fix.
Relocation involves new piping and fittings, and the device is retested afterward. If the old device is in good shape, we can often reuse it, which keeps the cost down.
Working with contractors
Construction projects have a lot of moving parts. We coordinate with general contractors, plumbers and landscapers to install the assembly at the right stage and test it once water is on.
Since final inspection often needs the startup report, we file it promptly.
Choosing materials and fittings
The assembly is only as good as what connects it. We use fittings rated for potable water and sized to match the device, with unions where they make future repairs easier. Larger assemblies get proper supports so the weight isn't hanging on the pipe.
Outdoor devices near sprinklers or soil get fittings that hold up to the weather. These details don't show on the test report, but they're the difference between an install that lasts and one that leaks in a few years.
Once it's in
The first test and report are included. From then on, plan on an annual test.
Why Whittier calls us
Certified testers. Calibrated gauges. Reports filed with your water district as part of every job. Prices given before any work starts.
Testing is $105 flat under 4 inches and $175 for 4 inches and up. We pick up seven days a week, 6am to midnight, book most visits within the week and take emergency calls 24/7.
What happens after you call: we confirm the address and device, give you a time window, and show up in it. The tester checks the device, runs the test and tells you the result on the spot. Pass: the report is filed that day. Fail: you get the reason and the price, and most repairs are done before we leave. Either way, you get a copy of everything for your records. Have several devices or properties in Whittier? Ask about multi-device pricing and due date tracking when you call.
Questions
Do you add a cage or cover?
If theft or freezing is a risk, we recommend one and include it in the quote.
Can an RP go underground?
No. The relief valve has to drain, so RPs go above ground.
Can a PVB go next to the meter?
Only if the meter is higher than every sprinkler it protects. On sloped yards it often needs to go uphill.
How long does installation take?
Most installs for 2-inch and smaller assemblies take a day.
Do you pour a pad for a cage?
Yes, when a cage is part of the job we include the pad it bolts to.
Can you move an existing assembly?
Yes. A moved assembly has to be retested afterward, and we include that.